Show simple item record

dc.rights.licensehttp://creativecommons.org/licenses/by-nc-sa/3.0/ve/
dc.contributor.authorOrtiz, Reynaldo
dc.contributor.authorNava, Lismar
dc.contributor.authorMartínez, Yris J.
dc.contributor.authorWeinhold, Elkis
dc.contributor.authorParedes R., Andreina
dc.date.accessioned2017-12-07T22:53:39Z
dc.date.available2017-12-07T22:53:39Z
dc.date.issued2017-01
dc.identifier.issn0543-517X
dc.identifier.urihttp://www.saber.ula.ve/handle/123456789/44159
dc.description.abstractSe desarrolló un método voltamperométrico simple para la determinación de citrato de sildenafil (CS). El método se basa en la reducción catódica directa del CS sobre un electrodo de carbón vítreo modificado con una película plomo (Pb/ CV) en solución reguladora de acetato. La respuesta voltamperométrica de CS sobre Pb/CV, muestra dos picos uno a -1,15 y otro a -1,25 V. Los resultados experimentales indican una excelente correlación lineal entre la corriente de pico y la concentración, en un rango de 2×10-5 a 1,2×10-4 M para ambos picos. Los límites de detección (LOD) de CS fueron 1,1×10-6 y 5,2×10-6 M, usando voltametría de barrido lineal y voltametría de pulso diferencial, respectivamente. El método fue aplicado con éxito a la determinación de CS en formulaciones comerciales (comprimidos y tabletas orodispersables), encontrándose valores muy similares a los declarados por el fabricante; los resultados se contrastaron con los obtenidos por un método espectrofotométrico reportado y no se encontraron diferencias estadísticas significativas.es_VE
dc.language.isoeses_VE
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectElectrodo de película de plomoes_VE
dc.subjectCitrato de sildenafiles_VE
dc.subjectDeterminaciónes_VE
dc.subjectVoltametríaes_VE
dc.titleDeterminación voltamétrica de citrato de sildenafil en formulaciones farmacéuticases_VE
dc.title.alternativeVoltammetric determination of sildenafil citrate in pharmaceuticals formulationses_VE
dc.typeinfo:eu-repo/semantics/article
dc.description.abstract1A simple voltammetric method for the determination of sildenafil citrate (SC) was developed. The method is based on the direct cathodic reduction of SC on a lead film modified glassy carbon electrode (LF/GCE) in acetate buffer. Voltammetric response of SC at LF/GCE, shows two peaks at -1.15 V and -1.25 V. Experimental results indicate an excellent linear correlation between the peak current and concentration in the range of 2×10-5 to 1,2×10-4 M for both peaks. The detection limits (LOD) for SC were equal to 1.1×10-6 and 5.2×10-6 M, using Linear Sweep and Differential Pulse voltammetry, respectively. The method was successfully applied to the determination of SC in pharmaceutical formulations (Pills and Orodispersible tablets) and the contents were in close agreement with those quoted by the manufacturer. The results were compared with those obtained by a reported spectrophotometric method and no statistically significant differences were found.es_VE
dc.description.colacion7-16es_VE
dc.description.emailreynaldo@ula.vees_VE
dc.description.emailymartin@ula.vees_VE
dc.description.emailweinhold@ula.vees_VE
dc.description.emailandrepar90@gmail.comes_VE
dc.description.frecuenciaSemestral
dc.identifier.depositolegalpp195802ME1003
dc.identifier.edepositolegalppi201202ME4102
dc.identifier.eissn2244-8845
dc.publisher.paisVenezuelaes_VE
dc.subject.facultadFacultad de Farmacia y Bioanálisises_VE
dc.subject.keywordsLead film electrodees_VE
dc.subject.keywordsSildenafil citratees_VE
dc.subject.keywordsDetermination voltammetryes_VE
dc.subject.publicacionelectronicaRevista de la Facultad de Farmacia
dc.subject.seccionRevista de la Facultad de Farmacia: Artículos Originaleses_VE
dc.subject.thematiccategoryMedicina y Saludes_VE
dc.subject.tipoRevistases_VE
dc.type.mediaTextoes_VE


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record