• español
    • English
    • français
    • português (Brasil)
  • español 
    • español
    • English
    • français
    • português (Brasil)
  • Login
Universidad de Los Andes

  • Inicio
  • Facultades
  • Unidades de Investigación
  • Investigadores
  • Revistas
  • Postgrados
  • Eventos
Ver ítem 
  •   SaberULA Repositorio Institucional de la Universidad de Los Andes, Mérida - Venezuela: Página Principal
  • Revistas
  • Revista Odontológica de Los Andes
  • Revista Odontológica de Los Andes - Vol. 021 - Nº 1
  • Ver ítem
  •   SaberULA Repositorio Institucional de la Universidad de Los Andes, Mérida - Venezuela: Página Principal
  • Revistas
  • Revista Odontológica de Los Andes
  • Revista Odontológica de Los Andes - Vol. 021 - Nº 1
  • Ver ítem
JavaScript is disabled for your browser. Some features of this site may not work without it.

Evaluación de la textura superficial en restauraciones dentales con resina compuesta obtenida entre tres sistemas de pulido

Thumbnail
Ver/
Ver texto completo (1.144Mb)
Fecha
2026-01-21
Autor
Becerra F., Natalia V.
Montoya D., Luis G.
Muñoz M., Rafael A.
Giménez, Blasmir
Palabras Clave
Resina compuesta, pulido, sistema de pulido, textura superficial, microscopio óptico, rugosímetro, rA, puntas de silicona, punta de goma, disco Soflex
Composite resin, polishing, polishing system, surface texture, optical microscope, roughness, rA, tips silicone rubber tip, disco Soflex resin
Metadatos
Mostrar el registro completo del ítem
Compartir por...
| | |
Resumen
La resina compuesta es un material restaurador ampliamente utilizado en odontología por sus propiedades estéticas. Para optimizar su desempeño clínico, es esencial un adecuado pulido. Este estudio tuvo como objetivo comparar la textura superficial de resinas compuestas pulidas con tres sistemas diferentes, evaluando la orientación y la rugosidad (Ra). Se realizó una investigación descriptiva, de diseño no experimental y transeccional. La muestra incluyó 30 dientes extraídos, distribuidos en tres grupos: D (discos Sof-Lex), S (puntas de silicona, dos pasos) y G (punta de goma, un paso). La orientación se evaluó mediante microscopio óptico y la rugosidad con rugosímetro Mitutoyo®. Los resultados mostraron que el grupo S obtuvo los valores de Ra más cercanos a cero y una orientación superficial más homogénea. El análisis estadístico mediante ANOVA, con prueba post-hoc de Tukey, reveló diferencias significativas entre los grupos (p < 0,001), permitiendo rechazar la hipótesis nula. Se concluye que el sistema de puntas de silicona en dos pasos (grupo S) produce una textura superficial significativamente menos rugosa (p < 0,001), en comparación con los otros métodos. Esto sugiere que dicho sistema es el más eficaz para lograrsuperficies lisas en restauraciones de resina compuesta.
URI
http://www.saber.ula.ve/handle/123456789/52175
Colecciones
  • Revista Odontológica de Los Andes - Vol. 021 - Nº 1
Información Adicional
Otros TítulosEvaluation of surface texture in dental restoration with composite resin obtained between three polishing systems
Correo Electróniconatabef@gmail.com
luisgmd95@gmail.com
ramm339@gmail.com
od.blasmirgimenez@gmail.com
ORCIDhttp://orcid.org/0009-0000-8799-5677
http://orcid.org/0000-0001-8332-2424
http://orcid.org/0009-0007-2136-8241
http://orcid.org/0001-1917-9173
ISSN1856-3201
Resumen en otro IdiomaComposite resin is a widely used restorative material in dentistry due to its aesthetic properties. To optimize its clinical performance, proper polishing is essential. This study aimed to compare the surface texture of composite resins polished with three different systems, evaluating surface orientation and roughness (Ra). A descriptive, non-experimental, cross-sectional design was used. The sample consisted of 30 extracted teeth, distributed into three groups: D (Sof-Lex™ discs), S (two-step silicone points), and G (one-step rubber point). Surface orientation was evaluated using an optical microscope, and roughness was measured with a Mitutoyo® profilometer. Results showed that group S had Ra values closest to zero and a more homogeneous surface orientation. Statistical analysis using ANOVA, followed by Tukey’s post-hoc test, revealed significant differences between groups (p < 0.001), leading to rejection of the null hypothesis. It is concluded that the two-step silicone point system (group S) produces a significantly smoother surface texture (p < 0.001) compared to the other methods. This suggests that the twostep system is the most effective in achieving smooth surfaces in composite resin restorations.
Colación120-138
PeriodicidadSemestral
Página Webhttp://erevistas.saber.ula.ve/odontoula
PaísVenezuela
InstituciónUniversidad de Los Andes
SecciónRevista Odontológica de Los Andes: Trabajos de Originales

Univesidad de Los Andes

  • Rectorado
  • Vicerectorado Académico
  • Vicerectorado Administrativo
  • Secretaría

Navegación por documentos

  • Por Fecha de Publicación
  • Por Autores
  • Por Títulos
  • Por Palabras Clave

Preguntas Frecuentes

  • ¿Cómo publicar?
  • ¿Cómo enviar o actualizar información?
  • ¿Cuál es la Licencia de Depósito de documentos en SaberULA?
  • ¿Qué es un Repositorio Institucional (RI)?
  • ¿Cómo obtengo RSS por tipo de documentos?

Ubícanos

  • emailsaber@ula.ve
  • +58-0274-240.23.43
  • Mérida - Venezuela

Síguenos

facebook  twitter   

Contacto | Sugerencias

Licencia Creative Commons Todos los documentos publicados en este repositorio se distribuyen bajo una
Licencia Creative Commons Atribución-NoComercial-CompartirIgual 3.0 Venezuela .

SaberULA Repositorio Institucional de la Universidad de Los Andes, Mérida, Venezuela 2018.

DSpaceDSpace software copyright © 2002-2016  DuraSpace.
Theme by  Atmire NV

 

 

Listar

Todo Saber-ULAComunidades & ColeccionesPor fecha de publicaciónAutoresTítulosMateriasEsta colecciónPor fecha de publicaciónAutoresTítulosMaterias

Mi cuenta

Acceder

Estadísticas

Ver Estadísticas de uso

Univesidad de Los Andes

  • Rectorado
  • Vicerectorado Académico
  • Vicerectorado Administrativo
  • Secretaría

Navegación por documentos

  • Por Fecha de Publicación
  • Por Autores
  • Por Títulos
  • Por Palabras Clave

Preguntas Frecuentes

  • ¿Cómo publicar?
  • ¿Cómo enviar o actualizar información?
  • ¿Cuál es la Licencia de Depósito de documentos en SaberULA?
  • ¿Qué es un Repositorio Institucional (RI)?
  • ¿Cómo obtengo RSS por tipo de documentos?

Ubícanos

  • emailsaber@ula.ve
  • +58-0274-240.23.43
  • Mérida - Venezuela

Síguenos

facebook  twitter   

Contacto | Sugerencias

Licencia Creative Commons Todos los documentos publicados en este repositorio se distribuyen bajo una
Licencia Creative Commons Atribución-NoComercial-CompartirIgual 3.0 Venezuela .

SaberULA Repositorio Institucional de la Universidad de Los Andes, Mérida, Venezuela 2018.

DSpaceDSpace software copyright © 2002-2016  DuraSpace.
Theme by  Atmire NV