dc.rights.license | http://creativecommons.org/licenses/by-nc-sa/3.0/ve/ | es_VE |
dc.contributor.author | Merchán-Castellanos, Nuri Andrea | |
dc.contributor.author | Aguilera-Becerra, Astrid Maribel | |
dc.contributor.author | Manrique, Wilfred Edilberto | |
dc.date.accessioned | 2021-05-27T04:29:14Z | |
dc.date.available | 2021-05-27T04:29:14Z | |
dc.date.issued | 2021 | |
dc.identifier.issn | 0798-2259 | |
dc.identifier.uri | http://www.saber.ula.ve/handle/123456789/47450 | |
dc.description.abstract | El objetivo del estudio fue desarrollar una metodología de
alta precisión que permitiera detectar y cuantificar residuos
de tetraciclina en quesos aplicando la técnica analítica de
cromatografía liquida de alta eficiencia (HPLC). Como resultado
se generó un método mediante el cual se detectaron residuos
de tetraciclina en matrices biológicas complejas como el queso.
Se establecieron condiciones de temperatura (30 °C), longitud
de onda (265 nanómetros (nm)), volumen (20 microlitros (μL))
y flujo de inyección (1 mililitro (mL)/minutos(min)), así como
la fase móvil utilizada con metanol: acetonitrilo: ácido oxálico
(74:13:13% volumen/volumen (v/v)) para la corrida en el equipo
HPLC. Se obtuvieron curvas de calibración con coeficiente
de determinación (R2) próximos a 1, con concentraciones
de soluciones estándar de 2,0 partes por millón (ppm), 1,5
ppm, 1,0 ppm, 0,8 ppm, 0,6 ppm, 05 ppm, para tetraciclina. El
método presentó límites de cuantificación para tetraciclina de
0,1 miligramos/Litro (mg/L) y límite de detección de 0,2 mg/L,
valores que se encuentran por debajo de los límites máximos
permisibles por la norma colombiana para leches. Por otra
parte, se establecieron condiciones para realizar el proceso de
extracción de los residuos de antibióticos en matrices biológicas
complejas, como buffer, tiempo y temperatura de centrifugación,
tipo de cartucho para purificación y reactivo de recuperación
entre otras. Se concluye que el porcentaje de recuperación fue
adecuado y se evidencia que el método permite la detección de
los residuos de antibióticos a partir de muestras biológicas. | es_VE |
dc.language.iso | es | es_VE |
dc.publisher | SaberULA | es_VE |
dc.rights | info:eu-repo/semantics/openAccess | es_VE |
dc.subject | Cromatografía líquida de alta precisión (HPLC) | es_VE |
dc.subject | Queso | es_VE |
dc.subject | Tetraciclina | es_VE |
dc.subject | Antibacterianos | es_VE |
dc.title | Desarrollo de un método de detección y cuantificación de residuos de tetraciclina en quesos por cromatografía líquida de alta eficiencia (HPLC) | es_VE |
dc.title.alternative | Deveploment of a method for detection and quantification of tetracycline residues in cheese by high-performance liquid chromatography (HPLC) | es_VE |
dc.type | info:eu-repo/semantics/article | es_VE |
dcterms.dateAccepted | 15/04/2020 | |
dcterms.dateSubmitted | 06/09/2020 | |
dc.description.abstract1 | The aim of this study was to develop a high-precision methodology
that would allow the detection and quantification of tetracycline
residues in cheeses using the Liquid Chromatography High
Efficiency (HPLC) analytical technique. As a result, a method
was generated in which tetracycline residues were detected
in complex biological matrices such as cheese. Conditions of
temperature (30 ° C), wave length (265 nanometres (nm)),
volume (20 microlitres (μL) and injection flow (1 millilitres mL /
minutes (min)) were established, as well as the mobile phase
used with methanol: acetonitrile: oxalic acid (74 : 13: 13%
volume/ volume (v/v)) for the assay on the HPLC machine.
Calibration curves with coefficient of determination (R2) close to
1 were obtained, with concentrations of standard solutions of 2.0
parts per million (ppm), 1.5 ppm, 1.0 ppm, 0.8 ppm, 0.6 ppm,
0.5 ppm, for tetracycline. The method presented quantification
limits for tetracycline of 0.1 milligrams/Litter (mg/L) and detection
limit of 0.02 mg/L, values that are below the maximum limits
allowed by the Colombian standard for milk. On the other hand,
conditions were established to carry out the extraction process
of the antibiotic residues in complex biological matrices, such as
buffer, centrifugation time and temperature, type of cartridge for
purification and recovery reagent, among others. It is concluded
that the recovery percentage was adequate, and it is evident
that the method allows the detection of antibiotic residues from
biological samples. | es_VE |
dc.description.colacion | 180-185 | es_VE |
dc.description.email | amaguilera@uniboyaca.edu.co | es_VE |
dc.identifier.depositolegal | pp199102ZU46 | |
dc.identifier.edepositolegal | ppi201502ZU4665 | |
dc.identifier.eissn | 2477-944X | |
dc.publisher.pais | Venezuela | es_VE |
dc.subject.institucion | Universidad del Zulia (LUZ) | es_VE |
dc.subject.institucion | Universidad de Los Andes (ULA) | es_VE |
dc.subject.keywords | Cromatography high pressure liquid (HPLC) | es_VE |
dc.subject.keywords | Cheese | es_VE |
dc.subject.keywords | Tetracycline | es_VE |
dc.subject.keywords | Anti-bacterial agents | es_VE |
dc.subject.publicacionelectronica | Revista Científica | |
dc.subject.seccion | Revista Científica: Artículos | es_VE |
dc.subject.thematiccategory | Medio Ambiente | es_VE |
dc.subject.tipo | Revistas | es_VE |
dc.type.media | Texto | es_VE |