Afficher la notice abrégée

dc.rights.licensehttp://creativecommons.org/licenses/by-nc-sa/3.0/ve/
dc.contributor.authorGuillén Guillén, Ana
dc.contributor.authorCalderón G., Laura M.
dc.contributor.authorBrunetto, Rosario
dc.contributor.authorLeón L., Andrés
dc.contributor.authorGallignani, Maximo A.
dc.contributor.authorPáez Márquez, María
dc.date.accessioned2012-02-24T14:51:57Z
dc.date.available2012-02-24T14:51:57Z
dc.date.issued2011-06-30
dc.identifier.issn0543-517-X
dc.identifier.urihttp://www.saber.ula.ve/handle/123456789/34534
dc.descriptionISSN-E: 2244-8845 PPI: 2012 02 ME 4102
dc.description.abstractUn método por cromatografía líquida de alta resolución en fase reversa ha sido desarrollado para la determinación simultánea del clorhidrato de propranolol y la hidroclorotiazida, con detección de clorotiazida como impureza de síntesis. La separación se realizó en una columna X-BridgeTM C18 250 mm x 4,6 mm x 5 µm a 35 ºC. La fase móvil, con caudal de 1,0 mL min-1, quedó constituida por la solución A: solución amortiguadora de 0,1 M KH2PO4 y 0,05 M de 1-heptano sulfonato de sodio, a un pH 3,0 y un solvente B: acetonitrilo, aplicando un sistema de gradiente. La detección se realizó en un sistema de arreglo de diodos a 270 nm. La respuesta lineal se logró en un rango de concentración de 2,2 - 53,0 µg mL-1 para el clorhidrato de propranolol, de 1,4 - 34,0 µg mL-1 para la hidroclorotiazida y de 0,1 - 3,5 µg mL-1 para la clorotiazida. Un diseño factorial completo de 8 experimentos se aplicó para evaluar el nivel de influencia del pH, la [KH2PO4] y la [1-HSS] de la disolución amortiguadora, en la respuesta termodinámica del sistema para cada uno de los analitos en estudio. Un diseño factorial fraccionado de 8 experimentos fue empleado para estudiar la respuesta cinética del sistema con respecto a factores como: el solvente (% B), la temperatura, el flujo y el pH. Ambos diseños estadísticos mostraron resultados válidos sobre el margen razonable de fluctuación para cada factor y su interacción, que permitieron garantizar la robustez del método desarrollado con un 95% de confianza.es_VE
dc.language.isoeses_VE
dc.publisherSABER-ULAes_VE
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectHidroclorotiazidaes_VE
dc.subjectClorhidrato de propranololes_VE
dc.subjectClorotiazidaes_VE
dc.subjectAntihipertensivoses_VE
dc.subjectCromatografía líquida de alta resoluciónes_VE
dc.subjectDiseño factoriales_VE
dc.subjectRobustezes_VE
dc.titleDesarrollo analítico por cromatografía líquida de alta resolución en fase reversa para la determinación simultánea de clorhidrato de propranolol, hidroclorotiazida y clorotiazida. Aplicación de diseño factorial para la robustez del métodoes_VE
dc.title.alternativeAnalytical development for reverse-phase high resolution liquid chromatography for the simultaneous determination of propranolol hydrochloride, hydrochlorothiazide and chlorothiazide. Application of factorial design to the robustness of the methodes_VE
dc.typeinfo:eu-repo/semantics/article
dc.description.abstract1A reverse-phase high performance liquid chromatographic method has been has been developed for the simultaneous determination of propranolol hydrochloride and hydrochlorothiazide, chlorothiazide sensing as an impurity of synthesis. The separation was performed on a C18 column X-BridgeTM 250 mm x 4.6 mm x 5 µm to 35 ºC. The mobile phase with flow rate of 1.0 mL min-1, was composed of solution A: 0.1 M buffer KH2PO4 and 0.05 M of 1-heptane sulfonate, pH 3.0 and solvent B: acetonitrile, using a gradient system. The detection was performed on a diode array system at 270 nm. The linear response was achieved in a concentration range of 2.2 to 53.0 µg mL-1 for propranolol hydrochloride, from 1.4 to 34.0 µg mL-1 for hydrochlorothiazide and 0.1 to 3.5 µg mL-1 for chlorothiazide. A full factorial design of 8 experiments was applied to assess the level of influence of pH, [KH2PO4] and [1-HSS] of the buffer solution, thermodynamics in the response of the system to each of the analytes under study. Fractional factorial design of 8 experiments was used to study the kinetic response of the system with respect to factors such as the solvent (% B), temperature, flow and pH. Both designs showed statistical valid results on reasonable margin of fluctuation for each factor and their interaction, which allowed guarantee the robustness of the method developed with 95 % confidence.es_VE
dc.description.colacion2-12es_VE
dc.description.emailanamilena@ula.vees_VE
dc.description.emailbrunetto@ula.vees_VE
dc.description.emailleonand@ula.vees_VE
dc.description.emailmaximo@ula.vees_VE
dc.description.frecuenciasemestral
dc.identifier.depositolegal195802ME1003
dc.publisher.paisVenezuelaes_VE
dc.subject.facultadFacultad de Farmacia y Bioanálisises_VE
dc.subject.keywordsHydrochlorothiazide propranolol hydrochloride
dc.subject.keywordsChlorothiazide
dc.subject.keywordsAntihypertensives
dc.subject.keywordsHigh resolution liquid chromatography
dc.subject.keywordsFactorial design
dc.subject.keywordsRobustness
dc.subject.publicacionelectronicaRevista de la Facultad de Farmacia
dc.subject.seccionRevista de la Facultad de Farmacia: Artículo Originales_VE
dc.subject.thematiccategoryMedicina y Saludes_VE
dc.subject.tipoRevistases_VE
dc.type.mediaTextoes_VE


Fichier(s) constituant ce document

Thumbnail
Thumbnail

Ce document figure dans la(les) collection(s) suivante(s)

Afficher la notice abrégée