Mostrar el registro sencillo del ítem

dc.rights.licensehttp://creativecommons.org/licenses/by-nc-sa/3.0/ve/
dc.contributor.authorSánchez Villalobos, Alfredo
dc.contributor.authorVillarroel, Regino
dc.contributor.authorOviedo, Ana
dc.contributor.authorSandrea, Gilberto
dc.contributor.authorBoscán, Julio
dc.contributor.authorPinto Patiño, Roymi
dc.contributor.authorPirela Larrazábal, Francisco
dc.contributor.authorBecerra Ramírez, Luís
dc.contributor.authorLópez, Edgar
dc.date.accessioned2009-09-22T20:45:34Z
dc.date.available2009-09-22T20:45:34Z
dc.date.issued2009-09-22T20:45:34Z
dc.identifier.urihttp://www.saber.ula.ve/handle/123456789/29443
dc.description.abstractSe evalúa la capacidad operativa de las pruebas diagnósticas: anillo de la leche (PAL), inmunoensayo enzimático indirecto (ELISA-i), rosa de bengala (RB) y ELISA competitivo (ELISA- c), utilizadas tras 5 años (2003-2007) de vigilancia epidemiológica para brucelosis bovina (Brucella abortus) en el municipio Machiques de Perijá, partiendo de la revalorización de un conjunto de muestras de leche y suero probados positivos y negativos. La garantía de diagnóstico previamente positivo fue alcanzada a través de evidencias epidemiológicas y positividad comprobada en suero sanguíneo al ensayo con antígeno buferado en placa y confirmación mediante fluorescencia polarizada (FP); sólo se consideraron negativos probados, los sueros y leches globales provenientes de animales negativos a FP que a lo largo del estudio no presentaron antecedentes serológicos alguno. Los resultados en leche muestran superioridad de ELISA-i versus PAL, en sensibilidad, 98,55 contra 56,52%; especificidad 99,41 y 98,82%; predicción positiva 98,58 y 95,12%; predicción negativa 99,49 y 84,84%; y cocientes de probabilidad. El nivel de concordancia entre los resultados y el verdadero estatus de las muestras fue también preferente para ELISA-i, 97,8 contra 55,3%. Las evidencias sobre sueros probados dejan en duda la contribución de RB en el diagnóstico, control y erradicación de la enfermedad en el área de estudio, al demostrarse valores medios de validez (169,92 versus 197,21) y seguridad (171,74 versus 197,02), además de bajos coeficientes de verosimilitud entre sus resultados. ELISA-c, en cambio, mantuvo excelente capacidad diagnóstica.es_VE
dc.language.isoeses_VE
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectBrucelosis bovinaes_VE
dc.subjectMonitoreo epidemiológicoes_VE
dc.subjectValidezes_VE
dc.subjectSeguridades_VE
dc.subjectCoeficiente de probabilidades_VE
dc.subjectDoble propósitoes_VE
dc.titleMonitoreo epidemiológico para brucella abortus en fincas doble propósito del municipio machiques de Perijá, Venezuela. Parte II: validez y seguridad de las pruebas anillo de la leche y rosa de bengalaes_VE
dc.title.alternativeEpidemiologic surveillance system for brucella abortus in dual purpose farms from machiques de perijá county, Venezuela. Part two: validity and accuracy of ring test and rose bengal testes_VE
dc.typeinfo:eu-repo/semantics/article
dc.description.abstract1The performance of the following diagnostic tests: Milk Ring Test (MRT), Indirect Enzyme-linked Immunosorbent Assay (iELISA), Rose Bengal Test (RBT) and Competitive ELISA (cELISA) used for 5 years (2003-2007) in the epidemiological surveillance system for bovine brucellosis (Brucella abortus) in Machiques de Perijá County was evaluated. For this purpose, milk and sera samples previously assessed through the abovementioned tests were reassessed to define their true condition (true positive or true negative). Samples were considered as true positive through epidemiological findings and a positive result in Buffered Plate Antigen Test, which was confirmed through Fluorescence Polarization Assay (FPA); samples were considered as true negative only when they were taken from FPA-negative animals that did not seroconvert during the study. Results from tests in milk showed a higher performance of iELISA versus MRT, in sensibility: 98.55 and 56.52%; in specificity: 99.41 and 98.82%; in positive predictive value: 98.58 and 95.12%; in negative predictive value: 99.49 and 84.84%; and in coefficients of probability, respectively. The level of agreement between test and true status of samples was higher in iELISA: 97.8 versus 55.3%. Results from true positive and true negative samples warrant a reappreciation of the contribution of RBT in diagnostics, control and eradication of brucellosis in the studied area, taking into account its medium values of validity (169.92 versus 197.21) and accuracy (171.74 versus 197.02), as well as its low coefficients of probability. By contrast, cELISA showed an excellent diagnostic performance.es_VE
dc.description.colacion466-474es_VE
dc.description.frecuenciaBimestrales_VE
dc.identifier.depositolegal199102ZU46es_VE
dc.subject.institucionUniversidad del Zulia (LUZ)es_VE
dc.subject.institucionUniversidad de Los Andes (ULA)es_VE
dc.subject.keywordsBovine brucellosises_VE
dc.subject.keywordsEpidemiologic surveillancees_VE
dc.subject.keywordsValidityes_VE
dc.subject.keywordsAccuracyes_VE
dc.subject.keywordsCoefficient of probabilityes_VE
dc.subject.keywordsDual purpose cattlees_VE
dc.subject.publicacionelectronicaRevista Científicaes_VE
dc.subject.seccionRevista Científica: Medicina Veterinariaes_VE
dc.subject.thematiccategoryMedio Ambientees_VE
dc.subject.tipoRevistases_VE
dc.type.mediaTextoes_VE


Ficheros en el ítem

Thumbnail
Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem