• español
    • English
    • français
    • português (Brasil)
  • español 
    • español
    • English
    • français
    • português (Brasil)
  • Login
Universidad de Los Andes

  • Inicio
  • Facultades
  • Unidades de Investigación
  • Investigadores
  • Revistas
  • Postgrados
  • Eventos
Ver ítem 
  •   SaberULA Repositorio Institucional de la Universidad de Los Andes, Mérida - Venezuela: Página Principal
  • Revistas
  • Revista Venezolana de Endocrinología y Metabolismo
  • Revista Venezolana de Endocrinología y Metabolismo Vol 4 Nº 2
  • Ver ítem
  •   SaberULA Repositorio Institucional de la Universidad de Los Andes, Mérida - Venezuela: Página Principal
  • Revistas
  • Revista Venezolana de Endocrinología y Metabolismo
  • Revista Venezolana de Endocrinología y Metabolismo Vol 4 Nº 2
  • Ver ítem
JavaScript is disabled for your browser. Some features of this site may not work without it.

Validez de la determinación de lípidos utilizando el analizador portátil colestech LDX

Thumbnail
Ver/
articulo4.pdf (58.99Kb)
portada4_2.jpg (8.836Kb)
Fecha
2009-08-14
Autor
Villarroel, Vanessa
Salas, Alba
Paoli, Mariela
Arata de Bellabarba, Gabriela
Palabras Clave
Cholestech LDX, Lípidos, Validez
Cholestech, Lipids, Accuracy
Metadatos
Mostrar el registro completo del ítem
Compartir por...
| | |
Resumen
Objetivos: Determinar la validez de los valores de lípidos registrados en sangre capilar con el equipo portátil Cholestech LDX Métodos: La precisión y sensibilidad de la determinación de lípidos utilizando el equipo portátil cholestech LDX se comparó con la determinación clásica de lípidos en el laboratorio. Se estudiaron 41 sujetos, voluntarios. Las determinaciones de colesterol total (Ct), triglicéridos (Tg), HDL colesterol (C-HDL) y LDL colesterol (CLDL) se realizaron en el laboratorio, por método enzimático utilizando el estuche comercial (CONCEPTA) y con el analizador portátil Cholestech LDX. Los resultados fueron comparados utilizando análisis estadísticos parametricos. Resultados: Al comparar las concentraciones de lípidos obtenidas con el Cholestech LDX y con el método de laboratorio no se obtuvieron diferencias estadísticamente significativas; la concentración promedio de Ct fue de 197±49 y de 196±44; la de Tgc fue de 157±18 y de 139±15; la de C-HDL fue de 43±2 y de 45±1; la de C-LDL fue de 120±6 y de 124±6respectivamente. La sensibilidad y especificidad obtenida con el cholestech LDX fue de 65% y 96% para Ct:, 100% y 83% para Tg; 90% y 70% para C-HDL; 57% y 93% para C-LDL. El valor predictivo positivo y el negativo fue: 92% y 79% para Ct; 64% y 100% para Tg; 53% y 95% para C-HDL; 67% y 90% para CLDL. La correlación entre los valores obtenidos con el analizador portátil y los valores obtenidos en el laboratorio fueron altamente significativas: r=0,747, p<0,01 para Ct; r=0,981, p<0,0001 para Tg; r=0,739, p<0,0001 para CHDL; r=0,737, p<0,0001para C-LDL Conclusiones: El analizador portátil para la determinación de lípidos es una alternativa confiable como método para realizar despistajes de factores de riesgo.
URI
http://www.saber.ula.ve/handle/123456789/29181
Colecciones
  • Revista Venezolana de Endocrinología y Metabolismo Vol 4 Nº 2
Información Adicional
Otros TítulosValidity of the cholestech analyzer for the measurement of lipids
Correo Electrónicopaolimariela@hotmail.com
arabella@intercable.net.ve
ISSN1690-3110
Resumen en otro IdiomaObjective: Evaluate the validity of Cholestech LDX analyzer for the measurement of lipids in fingerstick samples. Méthods: precision and accuracy of the Cholestech LDX analyzer was compared to classical laboratory method. In 41 adult’s total cholesterol (Tc), triglycerides (Tg), CDL cholesterol (HDL-C) and LDL cholesterol (LDL-C) levels were measured by analyzer Cholestech LDX and compared to those obtained by enzymatic method using CONCEPTA kits. Results were compared using parametric statistical analyses. Results: Comparison of lipids concentrations obtained from Cholestech LDX and laboratory method were not significantly different; mean lipid values were Ct: 197±49 and 196±44; Tg: 157±18 and 139±15; C-HDL: 43±2 and 45±1; C-LDL: 120±6 and 124±6 respectively. Sensitivity and specificity with Cholestech LDX were 65% and 96% Ct:, 100% and 83% Tg; 90% and 70% C-HDL; 57%andy 93% C-LDL. Positive and negative values were 92% and 79% Ct; 64% and 100% Tg; 53% and 95% C-HDL; 67% and 90% C-LDL. Lipids measurements by both techniques correlated satisfactorily: r=0.747, p<0.01 Ct; r=0.981, p<0.0001 Tg; r=0.739, p<0.0001 C-HDL; r=0.737, p<0.0001 C-LDL Conclusions: Cholestech LDX instrument for the measurement of lipids provided a reliable alternative for screening for risk factors.
Colación30-33
DependenciaSociedad Venezolana de Endocrinología y Metabolismo
Publicación ElectrónicaRevista Venezolana de Endocrinología y Metabolismo
SecciónRevista Venezolana de Endocrinología y Metabolismo: Trabajos Originales

Univesidad de Los Andes

  • Rectorado
  • Vicerectorado Académico
  • Vicerectorado Administrativo
  • Secretaría

Navegación por documentos

  • Por Fecha de Publicación
  • Por Autores
  • Por Títulos
  • Por Palabras Clave

Preguntas Frecuentes

  • ¿Cómo publicar?
  • ¿Cómo enviar o actualizar información?
  • ¿Cuál es la Licencia de Depósito de documentos en SaberULA?
  • ¿Qué es un Repositorio Institucional (RI)?
  • ¿Cómo obtengo RSS por tipo de documentos?

Ubícanos

  • emailsaber@ula.ve
  • +58-0274-240.23.43
  • Mérida - Venezuela

Síguenos

facebook  twitter   

Contacto | Sugerencias

Licencia Creative Commons Todos los documentos publicados en este repositorio se distribuyen bajo una
Licencia Creative Commons Atribución-NoComercial-CompartirIgual 3.0 Venezuela .

SaberULA Repositorio Institucional de la Universidad de Los Andes, Mérida, Venezuela 2018.

DSpaceDSpace software copyright © 2002-2016  DuraSpace.
Theme by  Atmire NV

 

 

Listar

Todo Saber-ULAComunidades & ColeccionesPor fecha de publicaciónAutoresTítulosMateriasEsta colecciónPor fecha de publicaciónAutoresTítulosMaterias

Mi cuenta

Acceder

Estadísticas

Ver Estadísticas de uso

Univesidad de Los Andes

  • Rectorado
  • Vicerectorado Académico
  • Vicerectorado Administrativo
  • Secretaría

Navegación por documentos

  • Por Fecha de Publicación
  • Por Autores
  • Por Títulos
  • Por Palabras Clave

Preguntas Frecuentes

  • ¿Cómo publicar?
  • ¿Cómo enviar o actualizar información?
  • ¿Cuál es la Licencia de Depósito de documentos en SaberULA?
  • ¿Qué es un Repositorio Institucional (RI)?
  • ¿Cómo obtengo RSS por tipo de documentos?

Ubícanos

  • emailsaber@ula.ve
  • +58-0274-240.23.43
  • Mérida - Venezuela

Síguenos

facebook  twitter   

Contacto | Sugerencias

Licencia Creative Commons Todos los documentos publicados en este repositorio se distribuyen bajo una
Licencia Creative Commons Atribución-NoComercial-CompartirIgual 3.0 Venezuela .

SaberULA Repositorio Institucional de la Universidad de Los Andes, Mérida, Venezuela 2018.

DSpaceDSpace software copyright © 2002-2016  DuraSpace.
Theme by  Atmire NV