dc.description.abstractEl propósito del presente estudio fue determinar las variaciones dimensionales del torque en brackets nuevos de acero inoxidable, de técnica arco recto, prescripción Roth, de tres casas comerciales. Se tomó una muestra de forma probabilística de 360 brackets, 120 de la casa comercial Ortho USA (Luminus), 120 de Ormco (Mini Twin) y 120 de Rocky Mountain Orthodontics (Mini Taurus), los cuales se dividieron por grupo dental según el arco dentario (superior e inferior), y por las diferencias en el torque de los brackets de cada casa comercial. El rango de tolerancia solo fue establecido por la casa comercial Ortho USA, de acuerdo a información suministrada por el fabricante fue ±1º. Los resultados muestran que para Ortho USA, los valores de torque obtenidos en los grupos dentales de caninos superiores e inferiores, incisivos inferiores y segundos premolares inferiores estuvieron cercanos al valor nominal. Para Ormco los valores del torque de los grupos dentales de caninos inferiores y segundos premolares inferiores fueron los más alejados del valor nominal, con una variación de 2°. Para Rocky Mountain Orthodontics los promedios para todos los grupos dentales se encontraron muy cercanos al valor nominal. Los brackets estudiados presentaron variados grados de imprecisión por exceso o defecto para la única casa comercial que declaró su tolerancia. Los brackets de las casas comerciales que no declararon la tolerancia parecieron más precisos, pero la falta de la información solicitada no permite extender las conclusiones más allá de los brackets medidos.es_VE
dc.language.isoeses_VE
dc.publisherSABER-ULAes_VE
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectBracketses_VE
dc.subjectTorquees_VE
dc.subjectAparatos preajustadoses_VE
dc.subjectMedidases_VE
dc.titleEvaluación de las variaciones dimensionales del torque de brackets nuevoses_VE
dc.title.alternativeEvaluation of dimensional variations of the torque of new bracketses_VE
dc.typeinfo:eu-repo/semantics/article
dc.description.abstract1The purpose of this study was to determine the dimensional variations of the torque of new stainless steel brackets, straight wire technique, with Roth prescription, of three different companies. A total of 360 brackets were chosen as the sample by a probability method; 120 of them from Ortho USA (Luminus), 120 from Ormco (Mini Twin) and 120 from Rocky Mountain Orthodontics, which were divided by dental group according to the dental arch (upper and lower) and differences in torque of the brackets from each commercial firms. The tolerance range was only established for the commercial firms Ortho USA, according to information provided by the manufacturer was ± 1°. The results show that for Ortho USA, torque values obtained in the dental groups of upper and lower canines, lower incisors and second premolars were close to the nominal values. For Ormco, torque values of dental groups lower canines and second premolars were the furthest from the nominal value, with a variation of 2 °. For Rocky Mountain Orthodontics the averages of all dental groups were very close to the nominal value. The brackets studied showed varying degrees of imprecision for excess or defect for the only company that declared its tolerance. The brackets of the commercial firms that didn’t report their tolerance appeared more accurately, but the lack of the requested information does not allow to extend the conclusions beyond the brackets measured.es_VE
dc.description.colacion14-24es_VE
dc.description.emailgladysca60@yahoo.eses_VE
dc.identifier.depositolegalPP200502ME2052
dc.publisher.paisVenezuelaes_VE
dc.subject.facultadFacultad de Odontologíaes_VE
dc.subject.keywordsBracketses_VE
dc.subject.keywordsTorquees_VE
dc.subject.keywordsPre adjusted applianceses_VE
dc.subject.keywordsMeasurementes_VE
dc.subject.publicacionelectronicaRevista Odontológica de Los Andes
dc.subject.seccionRevista Odontológica de Los Andes: Trabajos de Investigaciónes_VE
dc.subject.thematiccategoryMedicina y Saludes_VE
dc.subject.tipoRevistases_VE
dc.type.mediaTextoes_VE


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem